AKTC Lateral Rotation Mattress
Code: FHA-AK-OPTIMAL-DUAL-TURN
Availability: Pre-Order
HK$26,500.0
正式公開發售日期待定
Description

Features

The Optimal Dual Turn is an advanced multi-functional microcontroller programmed 9.0L+9.0L dual linear compressors digital pump with a detachable power cord dynamic mattress replacement system. The high flowrate fast inflation dual compressors digital pump has a precise digital pressure transducer which is able to reduce the power wattage once the pressure is reached therefore it is the most quiet, power efficiency, and extended lifetime pump. The digital pump has 20 minutes static mode, alternate mode with selectable cycle time, Constant Low Pressure (CLP) or pulsate mode with selectable cycle time, auto-firm mode, auto-detection mode, and an optional fowler detector. To insure patient's safety, the pump has audiovisual low pressure, power failure, and service alarms with error code

 

For the patient

  • Lateral rotation and alternating simultaneously in one system – Invention Patent I 575176 March 21, 2017.
  • TrueCare Alternating enhances the comfort for the patient by fully re-inflate all sets of air cells before the next set of air cells deflates – Invention Patent I 543733 August 1, 2016.
  • Innovative iLAL (independent Low Air Loss) effectively reduces the moisture and skin heat on the support surface by periodically providing a high volume of low air loss relief.
  • Adjustable digital comfort control with optional auto-detection providing the recommendation pressure setting using software algorithms.
  • Selectable 10, 15, 20 minutes alternating cycle time with LED display and static mode for nursing procedure.
  • Constant low pressure (CLP) mode puts the mattress in a low pressure static surface for patients who cannot have a moving surface but still require a pressure reduction surface.
  • Pulsate mode with adjustable cycle time provides a periodic pressure changing static surface.
  • Auto-Firm mode provides one-button inflation for patient transportation.
  • Audiovisual alarms (power failure, low pressure, and service alarm with error code). 
  • Medical grade vapor permeable and spill resistance with fire retardant cover keeps the moisture away from patient’s skin. Two high quality molded-tooth zippers cover for easy replacement and laundry.
  • Dual-way “Quick-CPR” provides immediate mattress deflation in case of emergency – USA patent 6,257,269 B1 May 3, 2000.
  • Two-stage fowler detector automatically stops turning at 20 degrees and increases the pressure output at 45 degrees to prevent “bottoming-out” when the patient is at backrest position.
  • Lateral rotation with three turning modes with adjustable angles and adjustable turning cycle time from 5-95 minutes – Left Turn, Full Turn, and Right Turn.